RETIRED ›
This product is no longer available.

Image Not Available

Services Available
Free Support No

Overview

Current Version: 2.1

The PC-OPC/10 offers ten licenses of PC-OPC at a reduced cost per copy. It is intended to allow data to be transferred from a LoggerNet server to multiple client computers.

The PC-OPC Server uses the OPC standard interface to allow third-party, OPC-compatible graphics packages to view data from the LoggerNet server. This software provides a simple browser interface that allows you to easily select the values you want to display. It also allows you to view input locations, final storage data, and LoggerNet communications server statistics, as well as perform control operations.

Read More

Detailed Description

PC-OPC/10 provides ten licenses of PC-OPC at a reduced cost per copy. It is intended to allow data to be transferred from a LoggerNet server to multiple client computers.

The PC-OPC Server uses a simple browse interface that:

  • Provides data via “data tags” to any SCADA or third-party software that supports OPC
  • Updates, or pushes, data to third-party software as the LoggerNet server collects it from the data logger(s)
  • Allows third-party software to set input locations, variables, ports, and flags in our data loggers

Many software and hardware products support OPC. Products that have been tested by Campbell Scientific include Iconics Genesis, Intellution IFIX, and National Instruments Lookout.

Specifications

Current Version 2.1
Data Access Standard Supports Data Access Standard 2.05a only.
Requirement Licensed copy of LoggerNet or LoggerNetAdmin must be running on the same PC or a remote PC that is accessible via TCP/IP.
Purchased Separately Yes
Dimensions 12.7 x 14.0 x 0.33 cm (5.0 x 5.5 x 1.3 in.)
Weight 453.6 lb (1.0 lb)

Compatibility

Note: The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.

Data Loggers

Product Compatible Note
21X (retired) The 21X requires three PROMs; two PROM 21X Microloggers are not compatible.
CR10 (retired)
CR1000 (retired)
CR1000X
CR10X (retired) LoggerNet is compatible with the mixed array, PakBus, and TD operating systems.
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired) LoggerNet is compatible with the mixed array, PakBus, and TD operating systems.
CR295X (retired)
CR300
CR3000 (retired)
CR310
CR500 (retired)
CR5000 (retired)
CR510 (retired) LoggerNet is compatible with the mixed array, PakBus, and TD operating systems.
CR6
CR800 (retired)
CR850 (retired)
CR9000 (retired)
CR9000X (retired)

Additional Compatibility Information

Requires a licensed copy of LoggerNet running on the same PC or a remote PC that is accessible via TCP/IP.

OPC Products

Many software and hardware products support OPC. Products that have been tested by Campbell Scientific include Iconics Genesis, Intellution IFIX, and National Instruments Lookout. PC-OPC supports Data Access Standard 2.05a only.

Computer

Minimum recommended hardware is 300 MHz Pentium II processor with 128 Mbyte of RAM and screen resolution of 800 x 600. Recommended computer operating systems are Windows Vista, 2000, and XP.


Frequently Asked Questions

Number of FAQs related to PC-OPC/10: 5

Expand AllCollapse All

  1. The PC-OPC Server demo enables users to verify if an OPC client will work with Campbell Scientific’s OPC server. The trial version doesn't actually connect to a LoggerNet server or provide any true data. It only provides mock data.

  2. The PC-OPC Server works with OPC Data Access Specification 2.05a.

  3. The blog article "How to Navigate the World of Software Upgrades, Patches, and Trials" explains the difference between patches (free of charge) and upgrades (for a fee). This example quickly shows the difference between an upgrade and a patch:

    Upgrade Patch

    Major version change, such as 1.3 to 2.0

    Minor version change, such as 1.3 to 1.4

    Typically requires purchase for a fee

    Free of charge

  4. If the OPC client software supports getting data from an SQL server, LoggerNet Database Software (LNDB) may be a more appropriate option than PC-OPC. LNDB stores a complete history of data tables retrieved from the data loggers in an SQL server. In contrast, PC-OPC only provides the last record from each data table in the LoggerNet cache when it is first started and any new records that are collected by LoggerNet while the PC-OPC Server is running. If the OPC client is storing PC-OPC data in its own database, gaps will be created (missing data) in the OPC client database if the PC-OPC Server, the OPC client, or both are not running when LoggerNet collects the data.

  5. Campbell Scientific data loggers cannot communicate directly with LabVIEW. However, after retrieving data collected by any of the Campbell Scientific data loggers and placing the data in the LoggerNet data cache, the data can be shared with LabVIEW using a LoggerNet client called PC-OPC. A trial version of PC-OPC is available in the Downloads section of the PC-OPC product page.  

    The PC-OPC Server software provides a standard interface that allows third-party OPC-compatible graphics packages, including LabVIEW, to display the data logger data.

    In addition to using the PC-OPC Server and the data socket feature in LabVIEW, communication can also be established using LoggerNet-SDK with ActiveX controls.


Listed Under

Other Accessory for the following products:

Privacy Policy Update

We've updated our privacy policy.  Learn More

Cookie Consent

Update your cookie preferences.  Update Cookie Preferences