Data Loggers / CR9000
RETIRED ›
This product is no longer available and has been replaced by: CR9000X.
CR9000 Measurement and Control System
Services Available
Repair No
Calibration No
Free Support No

Overview

The CR9000 was a modular, multiprocessor system that provided precision measurement capabilities in a rugged battery-operated package. Its Base System included a CR9031 CPU module, CR9041 A/D module, CR9011 power supply module, 2 Mbytes SRAM memory, 2 Mbytes Flash Memory, power supply module, and PC9000 Support Software for Windows. The on-board, BASIC-like programming language included data processing and analysis algorithms. Up to nine I/O modules (purchased separately) could be inserted into a CR9000 to configure a system for specific applications.

Read More

Images

Detailed Description

The CR9000 was a modular, multiprocessor system that provided precision measurement capabilities in a rugged battery-operated package. Its Base System included a CR9031 CPU module, CR9041 A/D module, CR9011 power supply module, 2 Mbytes SRAM memory, 2 Mbytes Flash Memory, power supply module, and PC9000 Support Software for Windows. The on-board, BASIC-like programming language included data processing and analysis algorithms. Up to nine I/O modules (purchased separately) could be inserted into a CR9000 to configure a system for specific applications.

Connection to a PC was accomplished via Ethernet, TLink fiber optic, parallel port, or serial interface using peripheral products.

The CR9000's internal battery had a 14 Ahr capacity per charge. Maximum operating current was 1 Amp from an unregulated 12 V supply.

Specifications

-NOTE-
  • Note: Additional specifications are listed in the CR9000(C) Specifications Sheet.
  • The card configuration used determines the following: the number of analog inputs, pulse counters, switched voltage excitations, switched current excitations, digital I/O ports, and continuous analog outputs.
A/D Bits 16
Scan Rate 4.5 kHz
Burst Mode 100 kHz

Compatibility

I/O Modules

Contemporary I/O modules can be used with either the CR9000 or CR9000X.

Software

The CR9000 came with PC9000 software, which has been replaced by RTDAQ software. RTDAQ software is not compatible with the CR9000. However, customers can upgrade a CR9000 datalogger to a CR9000X datalogger by replacing the CR9000's CR9031 CPU module with the contemporary CR9032 CPU module.

Communications

Connection to a PC was accomplished via Ethernet, TLink fiber optic, parallel port, or serial interface using peripheral products. Most of these peripheral products are now retired.


Frequently Asked Questions

Number of FAQs related to CR9000: 1

  1. The CR3000 program will have to be modified so that each measurement or control instruction includes the appropriate module number. Some parameters might differ as well.

Case Studies

Minnesota: Bridge Disaster Recovery
On August 1, 2007, the I-35W St. Anthony Falls Bridge over the Mississippi River in......read more
New York: Bridge Load Testing
Lehigh University researchers have been on the forefront of field instrumentation and testing of bridges,......read more
Space Research: Joint Damping Experiment
The Space Shuttle Endeavor carried the CR10 and CR9000 dataloggers into orbit as part of......read more
Korea: Flux Monitoring over a Rice Paddy
With instrumentation and help from Campbell Scientific, personnel from the Department of Atmospheric Sciences at......read more

Privacy Policy Update

We've updated our privacy policy.  Learn More

Cookie Consent

Update your cookie preferences.  Update Cookie Preferences