RETIRED ›
This product is no longer available and has been replaced by: CLARIVUE10.
OBS-3+ Turbidity Sensor
Services Available
Repair No
Calibration No
Free Support Yes

Overview

The OBS-3+ is a submersible turbidity probe that has sideways-facing optics. It uses OBS technology to measure suspended solids and turbidity for applications ranging from water quality in freshwater rivers and streams to sediment transport and dredge monitoring. Campbell Scientific data loggers measure the OBS-3+ probe's output and calculate turbidity.

Read More

Benefits and Features

  • Sideways facing optics avoid obstructions above and below the probe
  • Measures suspended solids and turbidity for up to 4000 NTUs
  • Provides a compact, low-power probe that is field proven
  • Compatible with most Campbell Scientific data loggers
  • Accurate and rugged
  • Stainless-steel body allows use down to 500 m in fresh water
  • Titanium body allows use down to 1500 m in fresh or salt water
  • Fitted with MCBH-5-FS, wet-pluggable connector—multiple mating cable length options available
  • Offers an optional five-point sedimentation calibration for better measurements (see Ordering Info on the web page)

Images

Detailed Description

The OBS-3+ uses its sideways-facing optics to emit a near-infrared light into the water. It then measures the light that bounces back from the water’s suspended particles.

If an obstruction is in the emitted light’s range, the light will scatter back and the turbidity reading will be too high. This probe's sideways-facing optics avoids obstructions above and below the probe. The OBS300 is available for locations that have obstructions around the sides of the probe.

OBS® is a registered trademark of Campbell Scientific.

Specifications

Range
  • 0 to 250 NTU
  • 0 to 500 NTU
  • 0 to 1000 NTU
  • 0 to 3000 NTU
  • 0 to 4000 NTU
Maximum Submersion Depth
  • 500 m (1640.5 ft) for stainless-steel body
  • 1500 m (4921.5 ft ) for titanium body
Concentration Accuracy
  • 2% of reading or 1 mg/l (whichever is larger) for mud
  • 4% of reading or 10 mg/l (whichever is larger) for sand
Maximum Concentration Range
  • Maximum concentration depends on sediment size, particle shape, and reflectivity.
  • 5,000 to 10,000 mg/l (for mud)
  • 50,000 to 100,000 mg/l (for sand)
Operating Temperature Range 0° to 40°C
Drift over Time < 2% per year
Maximum Data Rate 10 Hz
Minimum Warm-up Time 2 s
Infrared Wavelength 850 nm ±5 nm
Daylight Rejection -28 dB (re: 48 mW/cm-2)
Optical Power 2000 µW
Turbidity Accuracy 2% of reading or 0.5 NTU (whichever is larger)
Housing Material 316 stainless steel or titanium
Connector MCBH-5-FS, wet-pluggable
Diameter 2.5 cm (0.98 in.)
Height 14.7 cm (5.79 in.)
Weight 181.4 g (0.4 lb)

-2.5 Output Option

Output Voltage 0 to 2.5 V (over selected NTU range)
Supply Voltage 5 to 15 Vdc
Current Drain 15 mA

-5 Output Option

Output Voltage 0 to 5 V (over selected NTU range)
Supply Voltage 5 to 15 Vdc
Current Drain 15 mA

-20 Output Option

Output Voltage 4 to 20 mA (over selected NTU range)
Supply Voltage 9 to 15 Vdc
Current Drain 45 mA

Compatibility

Note: The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.

Data Loggers

Product Compatible Note
21X (retired)
CR10 (retired)
CR1000 (retired)
CR10X (retired)
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired)
CR295X (retired)
CR300
CR3000 (retired)
CR310
CR500 (retired)
CR5000 (retired)
CR510 (retired)
CR6
CR800 (retired)
CR850 (retired)
CR9000 (retired)
CR9000X (retired)

Frequently Asked Questions

Number of FAQs related to OBS-3+: 19

Expand AllCollapse All

  1. This has not been tested; however, it is likely that, as the sensor moves through the water, disturbances or bubbles are created that could distort the turbidity measurements.

  2. The beam divergence angle of the sensor is 42°. (Within this 42° cone, 95% of the beam power is contained.)

  3. These devices employ optical backscatter to measure light absorption and should produce comparable data, but variation is likely between sensors.

  4. The OBS-3+ and the OBS300 are essentially the same sensor but with differing optic placement. The OBS-3+ has sideways-facing optics, whereas the OBS300 has downward-facing optics.

  5. This sensor is available with two types of wipers.

    • The Hydro-Wiper-C is a battery powered mechanical wiper with a scheduled wiping frequency.
    • The Hydro-Wiper-D is a mechanical wiper that is controlled and powered by the data logger.
  6. Short Cut does not allow mV readings. To record the raw mV data before it is converted to NTU, open the Short Cut file in the CRBasic Editor, and alter the program manually.

  7. Sensors are calibrated at the factory for measurements up to 4,000 NTUs, if requested at the time of order. Sensor ranges cannot be adjusted outside the factory.

  8. The following are some suggestions:

    • Keep the optics clean.
    • Site-specific field calibration may be necessary for the best performance. 
    • Prevent the sensor from freezing.