083E-L Temperature and Relative Humidity Sensor
Services Available

Overview

The 083E, manufactured by Met One, is a temperature and relative humidity sensor that is commonly used with the WMS100 for wind-farm power performance measurements. The sensor is made of corrosion-resistant aluminum and polymer, and it is water-tight. Use this sensor to measure the full range of relative humidity, from 0 to 100%.

Read More

Images

083E sensor with the 41003-5 shield and crossarm (sold separately)
083E sensor with the 41003-5 shield and crossarm (sold separately)
083E sensor with the 41003-5 shield and crossarm (sold separately)
083E sensor with the 41003-5 shield and mast (sold separately)

Detailed Description

The 083E Relative Humidity Sensor measures variance in the capacitance change of a one micron thick dielectric polymer layer. This film absorbs water molecules through a metal electrode, and causes a capacitance change that is proportional to relative humidity. The thin polymer layer reacts quickly, providing up to 90% of the final value of relative humidity in fewer than five seconds. The sensor’s response is essentially linear, with small hysteresis, and negligible temperature dependence.

Temperature is measured with an internal thermistor.

Specifications

Measurement Description Temperature, relative humidity
Signal Type/Output Analog voltage
Input Power 4 mA at 12 Vdc (10 to 14 Vdc)
Diameter 1.91 cm (0.75 in.)
Length 19.05 cm (7.5 in.)
Weight 70.9 g (2.5 oz)

Relative Humidity

Sensor Thin film polymer capacitor
Measurement Range 0 to 100% RH
Response Time 10 s (with 2 m s-1 aspiration)
Temperature Coefficient 0.04% RH per °C
Accuracy ±2.0% from 0 to 100% humidity
Output Signal Range 0 to 1 Vdc

Air Temperature

Sensor Thermistor (precision multi-element)
Operating Temperature Range -50° to +50°C
Accuracy ±0.10°C (0.18°F)
Output Resistive

Compatibility

Note: The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.

Data Loggers

Product Compatible Note
21X (retired)
CR10 (retired)
CR1000 (retired)
CR1000X
CR10X (retired)
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired)
CR300
CR3000 (retired)
CR310
CR500 (retired)
CR5000 (retired)
CR510 (retired)
CR6
CR800 (retired)
CR850 (retired)
CR9000 (retired)
CR9000X (retired)

Additional Compatibility Information

Mounting

When exposed to sunlight, the 083E must be housed in a 41003-5 or RAD14 naturally aspirated radiation shield. The 41003-5 and RAD14 attach to a crossarm, mast, or user-supplied pipe with a 2.5 to 5.3 cm (1.0 to 2.1 in.) outer diameter.

The RAD14 uses a double-louvered design that offers improved sensor protection from driving rain, snow, and insect intrusion. A better measurement can be made by providing lower self-heating in bright sunlight combined with higher temperatures (> 24°C [~75°F]) and low wind speeds (< 2 m s-1 [~4.5 mph]).


Frequently Asked Questions

Number of FAQs related to 083E-L: 3

Expand AllCollapse All

  1. Most Campbell Scientific sensors are available as an –L, which indicates a user-specified cable length. If a sensor is listed as an –LX model (where “X” is some other character), that sensor’s cable has a user-specified length, but it terminates with a specific connector for a unique system:

    • An –LC model has a user-specified cable length for connection to an ET107, CS110, or retired Metdata1.
    • An –LQ model has a user-specified cable length for connection to a RAWS-P weather station.

    If a sensor does not have an –L or other –LX designation after the main model number, the sensor has a set cable length. The cable length is listed at the end of the Description field in the product’s Ordering information. For example, the 034B-ET model has a description of “Met One Wind Set for ET Station, 67 inch Cable.” Products with a set cable length terminate, as a default, with pigtails.

    If a cable terminates with a special connector for a unique system, the end of the model number designates which system. For example, the 034B-ET model designates the sensor as a 034B for an ET107 system.

    • –ET models terminate with the connector for an ET107 weather station.
    • –ETM models terminate with the connector for an ET107 weather station, but they also include a special system mounting, which is often convenient when purchasing a replacement part.
    • –QD models terminate with the connector for a RAWS-F Quick Deployment Station.
    • –PW models terminate with the connector for a PWENC or pre-wired system.
  2. Not every sensor has different cable termination options. The options available for a particular sensor can be checked by looking in two places in the Ordering information area of the sensor product page:

    • Model number
    • Cable Termination Options list

    If a sensor is offered in an –ET, –ETM, –LC, –LQ, or –QD version, that option’s availability is reflected in the sensor model number. For example, the 034B is offered as the 034B-ET, 034B-ETM, 034B-LC, 034B-LQ, and 034B-QD.

    All of the other cable termination options, if available, are listed on the Ordering information area of the sensor product page under “Cable Termination Options.” For example, the 034B-L Wind Set is offered with the –CWS, –PT, and –PW options, as shown in the Ordering information area of the 034B-L product page.

    Note: As newer products are added to our inventory, typically, we will list multiple cable termination options under a single sensor model rather than creating multiple model numbers. For example, the HC2S3-L has a –C cable termination option for connecting it to a CS110 instead of offering an HC2S3-LC model. 

  3. Many Campbell Scientific sensors are available with different cable termination options. These options include the following:

    • The –PT (–PT w/Tinned Wires) option is the default option and does not display on the product line as the other options do. The cable terminates in pigtails that connect directly to a data logger.
    • In the –C (–C w/ET/CS110 Connector) option, the cable terminates in a connector that attaches to a CS110 Electric Field Meter or an ET-series weather station.
    • In the –CWS (–CWS w/CWS900 Connector) option, the cable terminates in a connector that attaches to a CWS900-series interface. Connection to a CWS900-series interface allows the sensor to be used in a wireless sensor network.
    • In the –PW (–PW w/Pre-Wire Connector) option, the cable terminates in a connector that attaches to a prewired enclosure.
    • In the –RQ (–RQ w/RAWS Connector) option, the cable terminates in a connector that attaches to a RAWS-P Permanent Remote Automated Weather Station.

    Note: The availability of cable termination options varies by sensor. For example, sensors may have none, two, or several options to choose from. If a desired option is not listed for a specific sensor, contact Campbell Scientific for assistance.

Privacy Policy Update

We've updated our privacy policy.  Learn More

Cookie Consent

Update your cookie preferences.  Update Cookie Preferences