Overview

The SAT HDR GOES complied with the High Data Rate (HDR) specifications. This transmitter was NESDIS certified for low and high data rates—including 100, 300, and 1200 bps. The SAT HDR GOES supported transmission lengths from 1 to 120 seconds. Short transmission lengths enabled multiple stations to use the same NESDIS-assigned window. The transmitter had an internal GPS receiver that acquired time and the PPS signal.

Images


Specifications

Standard Operating Temperature Range -40° to +50°C
Dimensions 22.4 x 14.2 x 3.8 cm (8.8 x 5.6 x 1.5 in.)
Weight 771 g (1.7 lb)

Compatibility

Note: The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.

Data Loggers

Product Compatible Note
21X (retired)
CR10 (retired)
CR1000 (retired)
CR10X (retired)
CR200 (retired)
CR200X (retired)
CR206 (retired)
CR206X (retired)
CR211 (retired)
CR211X (retired)
CR216 (retired)
CR216X (retired)
CR23X (retired)
CR295 (retired)
CR295X (retired)
CR3000 (retired)
CR500 (retired)
CR5000 (retired)
CR510 (retired)
CR800 (retired)
CR850 (retired)
CR9000 (retired)
CR9000X (retired)

Downloads

SAT HDR GOES v.3.2.4 (505 KB) 02-01-2005

HDR GOES Support software and Operating System. SAT HDR GOES update for 2004 leap year and reset issues. Follow the instructions in the README.txt file for installing the new OS. ( Includes DCPComm version 1.9 build 3 with Windows XP Service Pack 2 support. )

CR10X OS v.1.23 (1.45 MB) 04-02-2010

Execution of this download installs the CR10X Operating System (Mixed-Array) on your computer.  

Note: The Device Configuration Utility is used to upload the included operating system to the datalogger.  Requires an SC32A or SC32B.


CR23X OS v.1.19 (690 KB) 03-28-2006

Execution of this download installs the CR23X Operating System (Mixed-Array) on your computer.

Note: The Device Configuration Utility is used to upload the included operating system to the datalogger.


CR510 OS v.1.15 (640 KB) 03-28-2006

Execution of this download installs the CR510 Operating System (Mixed-Array) on your computer.

Note: The Device Configuration Utility is used to upload the included operating system to the datalogger. Requires an SC32A or SC32B.