Limited Availability ›
This product has limited availability. Some accessories, replacement parts, or services may still be available when it is no longer available.
RF500M Radio Modem
Versatile Radio Modem
For networks with narrowband, UHF/VHF, licensed radios
weather applications water applications energy applications gas flux and turbulence applications infrastructure applications soil applications

Overview

The RF500M is a versatile radio modem for networks with UHF/VHF radios, typically serving as an interface between the data logger and radio. In addition to serving as a field modem connected to a data logger, the RF500M can also be used as a stand-alone repeater, or as a base-station modem connected to a computer. The RF500M is generally used with legacy or existing PakBus and mixed-array/dial-up networks. The RF500M works with our RF320-series radios, RF310-series radios, RF300-series radios, or any radio and modem combination that outputs a demodulated byte stream via RS-232.

For new installations, please consider one of our spread-spectrum radio solutions, or contact Campbell Scientific to discuss the use of other licensed radio options. 

The RF500M is an appropriate choice for any ALERT(1) store-and-forward repeaters or base-station-decoder applications. For ALERT2 applications, refer to the ALERT200 ALERT2 Basic Remote Data Platform.

Read More

Benefits and Features

  • Supports multiple radio configurations
  • Uses software (DevConfig) instead of hardware modifications to upgrade the operating system (OS) and change RF ID or other settings
  • Provides an RS-232 port (DTE) for modem configuration or attachment of an RS-232 radio
  • Avoids all collisions within a network, thus increasing polling speeds and reducing overall current drain

Images

Our RF networks require line-of-sight transmission. The mountain in this drawing obstructs line-of-sight with the base station. Use of the repeater station allows the base station to  receive data from the field stations.
The RF500M is used as a stand-alone repeater to provide a communication relay between stations that cannot communicate directly due to distance or obstacles.
At the field station, the RF500M modem functions as a communication interface between the datalogger and radio.

Detailed Description

The RF500M serves as a remote, repeater, and base station communication interface, generally for our licensed radio applications. It provides an interface between a data logger or computer and a radio and can be a stand-alone repeater when onsite logging is not required. The RF500M is powered from the CS I/O port or from an external power connection. This modem is software configurable, and has been designed to interface with data telemetry radios such as our RF320-, RF310-, and RF300-series VHF/UHF radios.

Operating System (OS) Options Descriptions

PakBus OS

Considered the standard for the RF500M, the -PB OS uses TDRF polling to quickly and efficiently move data through a network. Each station can be individually dialed by LoggerNet. This OS is compatible with -TD, -PB, and our current generation of PakBus data loggers.

ALERT Dual Mode OS

The ALERT (Automated Local Evaluation in Real Time) OS allows for transmission, repeating, and reception of binary ALERT formatted data. It is a derivative of the -PB OS, and therefore supports both ALERT and TDRF communications (allowing true two-way communication with a station). This OS is compatible with the CR200(X)-series, CR800-series, CR1000, and CR3000 dataloggers.

Dial OS

The dial OS works with both mixed-array and PakBus/table-based data loggers. Each station can be dialed by LoggerNet for downloading data, sending programs, and performing other tasks. Additionally, this OS allows stations to create point-to-point networks for sharing of measurement and control tasks.

Specifications

Voltage 7 to 20 Vdc (Can be provided by the CS I/O port.)
Active Current Drain < 8 mA RMS (@ 12 Vdc)
Temperature Response -25° to +50°C (standard)
Temperature Range -55° to +85°C (extended)
Dimensions 16.0 x 9.5 x 2.2 cm (6.31 x 3.69 x 0.88 in.)
Weight 0.18 kg (0.4 lb)

Transceiver Audio Output (pin 5)

J1 Jumper Configuration 310 mV peak-to-peak (Campbell Scientific adjusts the audio input gain so that it is compatible with J1.)
J3 Jumper Configuration 670 mV peak-to-peak

Compatibility

Data Logger Considerations

Time division polling and PakBus communications can be used in the same network as long as all of the data loggers are PakBus versions.

Compatible Contemporary Data Loggers

RF500M OS CR200(X) Series CR800/
CR850
CR1000 CR3000 CR6 CR9000X CR300 Series
-PB # ** #
-DA
-AL

Compatible Retired Data Loggers

RF500M OS CR
500
CR
510
CR
10
CR
10T
CR
10X
21X CR
23X
CR
9000
CR
5000
CR
7X
-PB
-DA
-AL

Notes:
#The RF500M cannot be a repeater while the modem is connected to a CR200(X) or CR300-series datalogger.
**The RF500M is only compatible with the CR6 when using -PB OS version 3 or later.
The -PB OS option for the RF500M is only compatible with the -PB and -TD OS for the CR510, CR10X, and CR23X.
The -DA OS option for the RF500M is NOT compatible with the -TD OS option for the CR510, CR10X, and CR23X.

Radios

Three jumper settings allow the RF500M to be used with a variety of radios. Though not a requirement, it is a good idea to standardize your network to use a single radio type. This practice simplifies operations and maintenance and provides the highest degree of interstation compatibility possible.

RF320 Series RF310 Series RF300 Series Calamp
DataRadio
DL-3400
Digital/
RS-232 Radio
RF200 RF100

Note:
The RF500M must have the -PB OS option to use a digital RS-232 radio with it.

Radio Modems and Radio Base Stations

Networks can contain a mixture of RF500M modems and other Campbell Scientific radio modems and base stations assuming they have compatible operating systems (see chart below).

Modem/
Base Station
-PB OS -DA OS -AL OS
RF500M -PB *
-DA
-AL
RF500B -PB *
-DA
-AL
RF310M -TD *
-MA
-AL
RF310B -TD *
-MA
-AL
RF315M -TD *
-MA
-AL
RF95A -TD *
-MA
-AL
RF232A -TD *
-MA
-AL

Notes:
*
 When taking advantage of TDRF and two-way communication.

Downloads

RF500M ALERT OS v.02 (770 KB) 01-04-2012

Execution of this download copies the ALERT Operating System (-AL) for the RF500M onto your computer. The ALERT (Automated Local Evaluation in Real Time) OS allows for transmission, repeating, and reception of binary ALERT formatted data. This OS is compatible with the CR200(X) series, CR800 series, CR1000, and CR3000.

Note: Requires Device Configuration Utility 2.01 or newer.

View Update History

RF500M DIAL OS v.01 (714 KB) 02-27-2012

Execution of this download copies the Dial Operating System (-DA) for
the RF500M onto your computer. The dial OS works with both mixed-array
and PakBus/Table based loggers with the exception of the CR200(X);
only the CS I/O port of the modem is used for data transfer. Each
station can be a point-to-point node and repeater and can be dialed by
LoggerNet for data transfer and remote administration.

Note: Requires Device Configuration Utility 2.01 or newer.


RF500M OS v.04 (492 KB) 02-04-2016

Execution of this download copies the PakBus Operating System (-PB) for the RF500M onto your computer. The -PB OS uses TD-RF polling to quickly and efficiently move data through a network. Additionally, each station can be individually dialed by LoggerNet. This OS is compatible with -TD, -PB, and our current generation of PakBus dataloggers.

Note: Requires Device Configuration Utility 2.01 or newer.

View Update History

Frequently Asked Questions

Number of FAQs related to RF500M: 7

Expand AllCollapse All

  1. The RF500M Radio Modem is warranted by Campbell Scientific, Inc., to be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless specified otherwise.
  2. Yes. When the RF500M is powered up (or whenever the internal processor is reset), each of the LED indicators on the modem will illuminate, cycle through a series of colors, and turn off. This is an indication that the RF500M is running the Power On Self-Test (POST). If the LEDs remain illuminated, this is an indication that the POST has failed.
  3. Usually, yes. Contact Campbell Scientific for a return material authorization number (RMA) and instructions for returning the unit for repair. Additional information is available on the Repair and Calibration page.

  4. No. The RF500M cannot be directly interfaced with a GPS receiver. However, most Campbell Scientific data loggers can be interfaced with the output from a GPS receiver and programmed to extract the positional information. This information can then be accessed via an RF500M/RF320 RF link.

  5. No. The CR1000KD is designed specifically for use on the CS I/O port of the CR800, CR1000, and CR6 dataloggers. 

  6. If the RF modem has a CS I/O connector, then it should be compatible with the CR10X without the use of an SC932A. Ensure that the RF modem’s firmware is compatible with the CR10X firmware.

    Note: RF modems that are not sold by Campbell Scientific will only interface with a CR10X via an SC932A or an SC105. 

  7. Engineering drawings, in general, are not made accessible to the public. For a specific question, contact Campbell Scientific for assistance.

Case Studies

Florida: Protecting an Endangered Species’ Habitat
The South Florida Water Management District (SFWMD) has a mission to manage and protect the......read more
North Carolina: ALERT Stations Updated
The Charlotte-Mecklenburg Flood Information and Notification System (FINS) consists of over 125 gaging stations spread......read more
Washington: ALERT Station Retrofit
The National Weather Service (NWS) operates a network of automated flood-warning stations around Mount St.......read more
Colorado: RWIS Data from ALERT System
Networks using the ALERT protocol are designed to give immediate access to data that indicates......read more
Virginia: ALERT System
In the late 1970s, the National Weather Service implemented the Integrated Flood Observing and Warning......read more
Oklahoma Mesonet: Meteorological Network
The Oklahoma Mesonet is a statewide environmental monitoring network developed through the cooperative efforts of......read more

Listed Under

Replacement Part for the following products:
This Product Replaced

Privacy Policy Update

We've updated our privacy policy.  Learn More

Cookie Consent

Update your cookie preferences.  Update Cookie Preferences