The EE181 is a rugged, accurate air temperature and relative humidity (RH) probe that is ideal for long-term, unattended applications. It includes a proprietary coating on the RH element that increases the life of the element and protects it from dirt, dust, salt, or other contaminants. A 1000 Ω PRT measures air temperature for the -40° to +60°C range. For optimum results, the EE181 should be recalibrated annually.
Measurement Description | Temperature, relative humidity |
Signal Type/Output | Analog voltage |
Supply Voltage | 7 to 30 Vdc (typically powered by the datalogger’s 12 V supply) |
Average Current Consumption | < 1.2 mA |
Filter Description | 30 μm pore size, stainless-steel mesh |
Startup Time | 2 s |
Housing Body Material | Plastic |
Housing Classification | IP65 |
Field Replaceable Chip or Recalibrate | Recalibrate |
Operating Temperature Range | -40° to +60°C |
Sensor Diameter | 2.1 cm (0.83 in.) |
Length | 16.0 cm (6.3 in.) |
Weight | 290 g (10.2 oz) with 5 m cable |
Air Temperature |
|
Sensing Element | 1000 Ω Platinum Resistance Thermometer (PRT) |
Measurement Range | -40° to +60°C |
Storage Temperature Range | -40° to +80°C |
Output Signal Range | 0 to 1 Vdc |
Accuracy | ±0.2°C (at +23°C) |
Relative Humidity |
|
Sensing Element | Capacitance |
Measurement Range | 0 to 100% RH (non-condensing) |
Output Signal Range | 0 to 1 Vdc |
Temperature Dependence | Typically 0.03% RH/°C |
Accuracy |
|
Note: The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.
Product | Compatible | Note |
---|---|---|
CR1000 (retired) | ||
CR1000X | ||
CR300 | ||
CR3000 (retired) | ||
CR310 | ||
CR350 | ||
CR6 | ||
CR800 (retired) | ||
CR850 (retired) |
When exposed to sunlight, the EE181 must be housed in a 10-plate solar radiation shield. Campbell Scientific recommends the MetSpec RAD10E, which uses a double-louvered design that offers improved sensor protection from driving rain, snow, and insect intrusion. This shield also has lower self-heating in bright sunlight combined with higher temperatures (> 24°C [~75°F]) and low wind speeds (< 2 m s-1 [~4.5 mph]), giving a better measurement.
The EE181 will work with R. M. Young 10-plate radiation shields (41003-5 or 41003-5A), but these shields require a special adapter (pn 28415) to accommodate the sensor girth.
The RAD10E and 41003-5 attach to a crossarm, mast, or user-supplied pipe with a 2.5 to 5.3 cm (1.0 to 2.1 in.) outer diameter. The 41003-5A radiation shield attaches to a CM500-series pole or a user-supplied pole with a 5.1 cm (2.4 in.) outer diameter.