The MetSens550 compact weather sensor measures wind speed and direction via an ultrasonic sensor, as well as air temperature, relative humidity, and barometric pressure, in a single, combined instrument mounted inside three double-louvered, naturally aspirated radiation shields with no moving parts. An integrated side connector allows users to connect a tipping bucket rain gauge. An integrated electronic compass allows the MetSens550 to provide accurate, relative wind direction measurements without being oriented in a particular way, making installation easier. WMO average wind speed and direction and gust, temperature, relative humidity, barometric pressure, absolute humidity, air density, wet bulb temperature, rainfall total, and rainfall intensity data are provided. The MetSens550 is compatible and easily integrated with the MeteoPV Solar Resource Platform and any Campbell Scientific data logger using SDI-12, RS-485, ModbusRS-485, or NMEA RS-232.
Measurements Made | Air temperature, barometric pressure, relative humidity, wind direction, and wind speed. (An integrated side connector allows users to connect a tipping bucket rain gauge.) |
Sampling Rate | 1 Hz |
Digital Communication Modes | Serial RS-232, RS-485, SDI-12, NMEA, Modbus, ASCII |
IP Rating | 66 |
Compliance |
|
Operating Temperature Range | -40° to +70°C |
Operating Voltage | 5 to 30 Vdc |
Typical Current Drain @ 12 Vdc |
|
Weight | 0.7 kg (1.5 lb) |
Air Temperature Measurement |
|
Measurement Range | -40° to +70°C |
Resolution | 0.1°C |
Accuracy | ±0.3°C (@ 20°C) |
Relative Humidity Measurement |
|
Measurement Range | 0 to 100% |
Resolution | 0.1 |
Accuracy | ±2% @ 20°C (10 to 90% RH) |
Barometric Pressure Measurement |
|
Measurement Range | 300 to 1100 hPa |
Resolution | 0.1 hPa |
Accuracy | ±0.5 hPa (@ 25°C) |
Wind Speed Measurement |
|
Measurement Range | 0.01 to 60 m s-1 |
Accuracy |
|
Resolution | 0.01 m s-1 |
Starting Threshold | 0.01 m s-1 |
Wind Direction Measurement |
|
Measurement Range | 0° to 359° |
Accuracy | ±3° (up to 60 m s-1) |
Resolution | 1° |
Precipitation Input |
|
Measurement Input Type | Triggering |
Range | 0 to 1000 mm h -1 |
Precipitation Resolution | From 0.01 mm |
Input to MetSens550 | Contact closure via an M8 male, 4-pin connector. (User-supplied 20 m cable or mating female connector required.) |
Compass |
|
Measurement Range | 0 to 359° |
Resolution | 1° |
Units of Measure | Degrees |
Accuracy | ±3° |
Three CR1000X data logger programs that read the MetSens550 measurements and sensor status. An example program is included for each output option (RS-232, Modbus, SDI-12).
Number of FAQs related to MetSens550: 1
We've updated our privacy policy. Learn More
Update your cookie preferences. Update Cookie Preferences