The Campbell Scientific Blog Your source for useful how-to information and helpful expert advice

About the Blog

The Campbell Scientific Blog has relevant information that expands your knowledge, answers your questions, and helps overcome your measurement challenges.


Search the Blog


Subscribe to the Blog

Set up your preferences for receiving email notifications when new blog articles are posted that match your areas of interest.


Area / Application

Product Category

Activity

Corporate / News

Enter your email address:



Suggest an Article

Is there a topic you would like to learn more about? Let us know. Please be as specific as possible.

Leave this field empty

Displaying 121 - 140 of 171 articles

Why Measurements on the Edge Require Careful Planning

Author: Shaun Dustin | Last Updated: 05/11/2016 | Comments: 1

why measurements on the edge require careful planning

I have worked with Boy Scouts for the past 18 years. When I need to talk to boys about taking risks, I share a story about three young men who were competing for a job to deliver goods over a mountain pass with hairpin turns... read more

Handling New Device Drivers in a Changing Windows World

Author: Dana Worley | Last Updated: 04/27/2016 | Comments: 0

handling new device drivers in a changing windows world

We've all been there. You open the box for some new toy such as a camera, printer, or even a data logger, and before you can get started, you are required to install a device driver. The device driver loads files onto your computer so... read more

How to Select the Correct Pulse Type for Your Measurements

Author: Jacob Davis | Last Updated: 04/21/2016 | Comments: 0

how to select the correct pulse type for your measurements

Have you ever had a sensor work on a P (pulse) data logger terminal, but not on a C (control) terminal? Is the list of choices for the PConfig parameter in the PulseCount() instruction daunting? Campbell Scientific data loggers offer several options for measuring pulse... read more

How to Navigate the World of Software Upgrades, Patches, and Trials

Author: Dana Worley | Last Updated: 04/13/2016 | Comments: 0

how to navigate the world of software upgrades, patches, and trials

You may find it a little confusing to differentiate between software upgrades and patches. For example, when do you need which one? When is there a fee for a software release, and when is a release free of charge? With the recent release of the new... read more

How to Access Live Measurement Data Using Modbus

Author: Paul Smart | Last Updated: 04/07/2016 | Comments: 24

how to access live measurement data using modbus

Did you know that you can turn your Campbell Scientific data logger into a Modbus TCP/IP server? Do you know why that’s a good idea? Campbell Scientific data loggers are commonly used as Modbus server devices. This means that the data logger is configured to... read more

Understanding the Ins and Outs of RF Connectors

Author: Sam Utley | Last Updated: 03/30/2016 | Comments: 4

understanding the ins and outs of rf connectors

While you may have no problem identifying which standard polarity RF connectors are pin (male) or socket (female), do you find it difficult to identify the gender of reverse polarity connectors? If so, don’t worry. You are certainly not alone. In addition to the gender... read more

5 Steps to Post Your CR6 Data to Weather Underground

Author: Sam Utley | Last Updated: 03/23/2016 | Comments: 10

5 steps to post your cr6 data to weather underground

Note: It appears that after this blog article was written, Weather Underground has been phasing out the “PWS – Upload Protocol.” The following tutorial may or may not work currently or in the future. However, it continues to offer some insight into structuring a CRBasic... read more

10+ Reasons to Be Excited about the New CR300 Datalogger

Author: Robin Deissinger | Last Updated: 03/16/2016 | Comments: 3

10+ reasons to be excited about the new cr300 datalogger

In this short interview, Kevin Rhodes, the product manager for the new CR300, tells us how this new data logger will be helpful to Campbell Scientific customers and why he thinks the CR300 is a great value. Kevin is the Director of Product Management at... read more

6 Steps to Easily Parse Data from a Trusted Source

Author: Gary Roberts | Last Updated: 03/02/2016 | Comments: 1

6 steps to easily parse data from a trusted source

Would it be helpful to include data from a reputable source with your own data? If you have permission to use another source’s data for free or by agreement, how can you easily extract the specific data you want to use without doing a lot... read more

9 Tips for Proper Battery Care

Author: Brad Maxfield | Last Updated: 02/17/2016 | Comments: 1

9 tips for proper battery care

In honor of National Battery Day, celebrated annually on February 18th, we’d like to take a moment to remind you of some tips for safely handling, storing, and using batteries in conjunction with your Campbell Scientific equipment. While it may be easy to overlook the proper... read more

Helpful Hints for Updating Your Data Logger's OS

Author: Janet Albers | Last Updated: 02/10/2016 | Comments: 0

helpful hints for updating your data logger's os

Periodically we release new operating systems (OSs) that include new functions and instructions, as well as enhancements or bug fixes for existing functions and instructions. If you are asked to update your OS or need a newly added feature for your application, this article provides... read more

Mobile App Joins the LoggerNet Family

Author: Dana Worley | Last Updated: 02/03/2016 | Comments: 2

mobile app joins the loggernet family

We’ve recently had an exciting new addition to our family of LoggerNet datalogger support software. In this brief article, I’ll introduce you to this mobile app and tell you how you can get it free of charge. You are probably familiar with LoggerNet, our PC-based software... read more

How to Handle Common Issues with USB to RS-232 Adapter Cables

Author: Jacob Davis | Last Updated: 01/27/2016 | Comments: 12

how to handle common issues with usb to rs-232 adapter cables

Have you had difficulty using a USB to RS-232 adapter to connect your RS-232 device to a computer? If so, you are not alone. Our customers frequently encounter issues with these adapters. In this article, I’ll briefly discuss the origin of these issues and provide... read more

Getting to Know DNP3

Author: Paul Smart | Last Updated: 01/20/2016 | Comments: 0

getting to know dnp3

Have you heard of DNP3 but been unsure of what it is or what it’s used for? In this brief article, I’ll introduce you to this communications protocol, its role in SCADA applications, and how you can use it with your Campbell Scientific equipment and... read more

How to Programmatically Access Stored Data Values

Author: Janet Albers | Last Updated: 01/13/2016 | Comments: 16

how to programmatically access stored data values

After you store measurements and other data in your data logger’s tables, how do you access that data to perform operations in your CRBasic program? Where can you get an all-access pass to your data? This article will explain how you can use a special... read more

How to Convert Wind Directions in Degrees to Compass Directions

Author: Jacob Davis | Last Updated: 01/06/2016 | Comments: 2

how to convert wind directions in degrees to compass directions

Do you feel lost when sifting through wind direction data that is listed in degrees? For example, can you picture in your mind what direction 195 degrees is? Would it be easier if your data logger could put your data in compass directions instead? In... read more

Use Time Intervals for More than Storing Data: Decisions and Control

Author: Janet Albers | Last Updated: 12/30/2015 | Comments: 2

use time intervals for more than storing data: decisions and control

We all know that Campbell Scientific data loggers are really good at taking measurements and storing data. But did you know that they can also make decisions and control other devices? Often, device control is done based on a time interval. This article briefly illustrates... read more

4 Tips to Successfully Run an MD485 Network with Extreme Cable Lengths

Author: Andrew Sandford | Last Updated: 12/23/2015 | Comments: 0

4 tips to successfully run an md485 network with extreme cable lengths

Do you have a network of devices, connected using MD485 interfaces, so spread out that extremely long cables are required? Are you worried that the distances, and resultant cable lengths, may be causing communication problems? In this brief article, we’ll look at four tips that... read more

Website Redesign Offers Better Device Experience

Author: Robin Deissinger | Last Updated: 12/16/2015 | Comments: 0

website redesign offers better device experience

Have you found it somewhat difficult to navigate our website on a mobile device? Have you been a little bit frustrated by web pages that didn’t resize correctly to fit your device’s screen? To address these issues, our Web Development and Communications team has been busy... read more

How to Access and Control Your Raven Modem via TCP/IP

Author: Gary Roberts | Last Updated: 12/09/2015 | Comments: 1

how to access and control your raven modem via tcp/ip

Have you ever wanted the ability to control your Raven cellular modem with your data logger? Would it be nice to be able to get data on the health of your cellular modem and its data network? Maybe you even want to reset your Raven... read more

We're active on social media!
Stay informed with our latest updates by following us on these platforms: